DA050-090-A0 DA100-120-B0 DA220-120-A0 DA420-120-A0 DA128-240-A0 Inverter 2in1

DA050-090-A0

Input Voltage :
9VDC (6V~12V) 
Input Current :
TYPICAL: 0.5A; MAX: 0.75A 
Dimension :
103mm x 14mm x 7mm  (L x W x H)
Description :
This DC to AC inverter designs for 7” single CCFL (Cold Cathode Fluorescent Lamp) LCD panels, LG. PHILIPS: LT070W02
Features :
  • Single lamp current is measured with current meter for high frequency as show below
  • Our inverters have a built-in 1A Fuse
  • Lamp frequency shall be detached from the horizontal synchronous frequency and its harmonics as far as possible in order to avoid interference
  • The waveform of the inverter output voltage shall be area symmetric and the design of our inverters have specification for the modularized lamps
  • To avoid over-shoot and inrush current problems, the design of our inverter have soft-startup
TOP

DA100-120-B0

Input Voltage :
12VDC (10.8V~13.2V) 
Input Current :
TYPICAL: 1A; MAX:1.5A 
Dimension :
150mm x 40mm x 12mm (L x W x H)
Description :
This DC to AC inverter designs for 15” dual CCFL (Cold Cathode Fluorescent Lamp) LCD panels. HANNSTAR: HSD150MX15-B & CPT: CLAA150XP01& CMO: M150X4-L06
Features :
  • Dual lamp current is measured with current meter for high frequency as show below
  • Our inverters have a built-in 2A Fuse
  • Lamp frequency shall be detached from the horizontal synchronous frequency and its harmonics as far as possible in order to avoid interference
  • The waveform of the inverter output voltage shall be area symmetric and the design of our inverters have specification for the modularized lamps
  • To avoid over-shoot and inrush current problems, the design of our inverter have soft-startup
TOP

DA220-120-A0

Input Voltage :
12VDC (10.8V~13.2V) 
Input Current :
TYPICAL: 1.8A; MAX:2.1A     
Dimension :
164mm x 40mm x 15mm  (L x W x H)
Description :
This DC to AC inverter designs for 17” 2 dual CCFL(Cold Cathode Fluorescent Lamp) LCD panels. CHIMEI:M170E6-L01; SAMSUNG:LTM170W1-L01
Features :
  • Dual lamp current is measured with current meter for high frequency as show below
  • Our inverters have a built-in 2A x 2 Fuse
  • Lamp frequency shall be detached from the horizontal synchronous frequency and its harmonics as far as possible in order to avoid interference
  • The waveform of the inverter output voltage shall be area symmetric and the design of our inverters have specification for the modularized lamps
  • To avoid over-shoot and inrush current problems, the design of our inverter have soft-startup
TOP

DA420-120-A0

Input Voltage :
12VDC (10.8V~13.2V) 
Input Current :
TYPICAL: 3A; MAX:3.5A     
Dimension :
194mm x 48m x 12mm  (L x W x H)
Description :
This DC to AC inverter designs for 20” 6 CCFL (Cold Cathode Fluorescent Lamp) LCD panels.
Features :
  • Dual lamp current is measured with current meter for high frequency as show below
  • Our inverters have a built-in 2A x 2 Fuse
  • Lamp frequency shall be detached from the horizontal synchronous frequency and its harmonics as far as possible in order to avoid interference
  • The waveform of the inverter output voltage shall be area symmetric and the design of our inverters have specification for the modularized lamps
  • To avoid over-shoot and inrush current problems, the design of our inverter have soft-startup
TOP

DA128-240-A0

Input Voltage :
24VDC (22.5V~25.5V) 
Input Current :
TYPICAL: 5A; MAX:7A   
Dimension :
320mm x 120mm x 10mm  (L x W x H)
Description :
This DC to AC inverter designs for 30” 16 CCFL (Cold Cathode Fluorescent Lamp) LCD panels.
Features :
  • Dual lamp current is measured with current meter for high frequency as show below
  • Our inverters have a built-in 2A x 2 Fuse
  • Lamp frequency shall be detached from the horizontal synchronous frequency and its harmonics as far as possible in order to avoid interference
  • The waveform of the inverter output voltage shall be area symmetric and the design of our inverters have specification for the modularized lamps
  • To avoid over-shoot and inrush current problems, the design of our inverter have soft-startup
TOP

PS260-130-A0

Input Voltage :
90 – 264 VAC
Input Current :
1.0 A MAX     
Dimension :
166mm x 130mm x 30mm (L x W x H)
Description :
This product is AC to DC power supply and DC to AC inverter that designs for 17” 2 dual CCFL (Cold Cathode Fluorescent Lamp) LCD monitor or LCD TV. CHIMEI:M170E6-L01; SAMSUNG:LTM170W1-L01
Features :
  • Wide input voltage: 90 – 264VAC (Power supply section)
  • Dual lamp current is measured with current meter for high frequency as show below
  • Inverters section have a built-in 2A x 2 Fuse
  • Lamp frequency shall be detached from the horizontal synchronous frequency and its harmonics as far as possible in order to avoid interference
  • The waveform of the inverter output voltage shall be area symmetric and the design of our inverters have specification for the modularized lamps
  • To avoid over-shoot and inrush current problems, the design of our inverter have soft-startup
TOP